CPSC says more than 200 people in the United States die each year from non-fire carbon monoxide poisoning linked to consumer products, and more than 100 of those deaths are linked to portable generators. The rule that matters most: outdoors only, at least 20 feet from the house, exhaust pointed away.
The CPSC rules
These are CPSC’s own words and numbers, from its Carbon Monoxide Information Center and a May 27, 2026 news release. CPSC also says that one portable generator can produce the same amount of carbon monoxide as hundreds of cars.
- Never use a portable generator inside homes, garages, basements, crawlspaces, sheds or other enclosed areas, even if doors or windows are open.
- Use generators outdoors only, at least 20 feet from homes and buildings, with the exhaust directed away from windows, doors and vents.
- Install battery-operated CO alarms, or alarms with battery backup, on every level of the home and outside sleeping areas. Interconnected alarms are best.
- Test alarms monthly and replace batteries if needed. Never ignore an alarm when it sounds: get outside, then call 911.
- Never use charcoal indoors. Do not cook on a charcoal grill in a garage, even with the door open.
Ready.gov, from FEMA, gives the same 20 feet and adds that generators and fuel should be kept at least that far from windows, doors and attached garages.
What carbon monoxide does
CPSC calls CO the “Invisible Killer”: a colorless, odorless, poisonous gas. Its news release says it can kill within minutes, often before victims recognize symptoms.
The symptoms CPSC lists are headache, dizziness, weakness, nausea, vomiting, sleepiness and confusion. If you suspect CO poisoning, get outside to fresh air immediately and then call 911. We are not medical advisers: this is the agency’s guidance, with its pages named in the facts table at the end.
What the CPSC staff counted
CPSC staff compiled fatal non-fire CO incidents tied to engine-driven tools from 2012 to 2022 that were reported to them as of April 17, 2023. The report says the information “does not represent a complete set of all incidents” and is a “minimum count”. The table gives the main findings, each taken from the Executive Summary or Table 11.
| Measure | Value | Where |
|---|---|---|
| Deaths a year from non-fire CO linked to consumer products | More than 200 | CPSC CO Information Center |
| Of those, linked to portable generators | More than 100 | CPSC CO Information Center |
| Generator CO deaths in the staff report, 2012 to 2022 | 789 | CPSC staff report, Table 11 |
| All engine-driven tool CO deaths, 2012 to 2022 | 872 from 699 incidents | CPSC staff report, Executive Summary |
| Generators only | 749 deaths (86%) from 583 incidents | CPSC staff report, Executive Summary |
| Deaths in fixed-structure homes | 553 deaths from 414 incidents | CPSC staff report, Executive Summary |
| Of those, no apparent ventilation of the exhaust attempted | 66% | CPSC staff report, Executive Summary |
| Generator-related deaths at residential locations | 77% | CPSC staff report, Executive Summary |
| Deaths when the generator was outdoors | 5% of generator-related deaths | CPSC staff report, Executive Summary |
| Reason: power outage | 103 incidents, 139 deaths | CPSC staff report, Executive Summary |
| Reason: power shut-off | 86 incidents, 117 deaths | CPSC staff report, Executive Summary |
| Reason: power to temporary locations | 114 incidents, 139 deaths | CPSC staff report, Executive Summary |
| Deaths in the four colder months, Nov. to Feb. | 45% of engine-driven tool deaths | CPSC staff report, Executive Summary |
| Deaths where a CO alarm was known to be present | 33 (4%) | CPSC staff report, Executive Summary |
Source: CPSC, Carbon Monoxide Information Center, cpsc.gov; CPSC staff report, Fatal Incidents Associated with Non-Fire CO Poisoning from Engine-Driven Generators and Other Engine-Driven Tools, 2012-2022 (Apr. 2023 data). The staff report is marked as not reviewed or accepted by the Commission; the incident counts are a minimum, not a full count. Retrieved 2026-10-02. CSV, 14 rows.
Reported generator-related CO deaths by year, 2012 to 2022, 2012 to 2022: 11 rows
| Year | Deaths reported to CPSC |
|---|---|
| 2012 | 49 |
| 2013 | 59 |
| 2014 | 49 |
| 2015 | 77 |
| 2016 | 75 |
| 2017 | 83 |
| 2018 | 76 |
| 2019 | 95 |
| 2020 | 104 |
| 2021 | 85 |
| 2022 | 37 |
11 rows from EIA retail sales.
CSVTable 11 of the report lists 789 generator-related deaths over the eleven years, with the highest yearly count in 2020 (104). The last two years are incomplete.
Where and why people were hurt
The report’s pattern is plain. Most deaths were at home, and most were with the generator inside or close to the living space. In 66% of fixed-structure home deaths for which information was available, no apparent ventilation of the exhaust was attempted. The report also notes that 64% of those incidents were in houses under 1,500 square feet.
The generator was outdoors in 5% of generator-related deaths. In those cases it sat close enough to windows, air conditioners or other openings to let CO get inside. That is why the 20 feet matters.
One 2021 case in the report involved a generator with a CO shutoff feature, advertised as certified to ANSI/PGMA G300-2018. It was outside the home, under eaves with soffit vents into the attic, with its exhaust aimed at a closed door. The report says it did not shut off. A safety feature is not a reason to move the generator closer.
Power shut-offs by the utility, for a bill dispute, nonpayment or another reason, were behind 86 incidents and 117 deaths. If you are facing a shutoff for unpaid bills, there may be help and legal protections: see shutoff rules by state and your state help page before you turn to a generator.
Alarms
Only 33 deaths, 4% of engine-driven tool deaths in the report, were in incidents where an alarm was known to be present. In 17 of those, the alarm was not working: no batteries, batteries put in wrong, drained batteries, no current, or it did not sound for an unknown reason. In 13, the alarm sounded, but the signal was misunderstood, the alarm was disarmed, or it sounded inside the house while the death was in an attached garage.
That is the case for battery backup, monthly tests, and getting out the moment an alarm goes off.
What to look for when you buy
CPSC’s 2026 release says to look for portable generators that have a CO shut-off safety feature, which automatically shuts the unit off when dangerous CO builds nearby. It says models certified to the latest PGMA G300-2023 and UL 2201-2023 standards include CO safety technologies meant to reduce poisoning risk, and that UL 2201 models also have reduced CO emissions.
It also says to read the labels, instructions and warnings in the manual, and to check and maintain the generator. Ready.gov adds: keep the generator dry, connect appliances with heavy-duty extension cords, and let it cool before refueling, because spilled fuel can ignite on hot parts. Touching a wet generator or a device plugged into one can cause shock.
What you are trying to run, our scenario
People ask how big a generator they need. We cannot tell you: the listings give running watts, not starting surge, and your generator’s manual gives its ratings. What we can do is show running watts of common loads from the ENERGY STAR lists.
| Load | Running watts, median | How we get it |
|---|---|---|
| Full-size refrigerator, average draw | 52 | Annual kWh median of the ENERGY STAR list divided by 8,760 hours |
| Television | 96 | Median average on-mode power, ENERGY STAR list |
| Ceiling fan, high speed | 30 | Median high-speed power, ENERGY STAR list |
| Window air conditioner | 709 | Median Btu per hour over CEER, ENERGY STAR list |
| Central air conditioner, 3-ton class | 2,169 | Median Btu per hour over SEER2, ENERGY STAR heat pump list |
Source: ENERGY STAR product lists, via data/appliances_es.json (2 Oct 2026). Running watts only: the lists give no starting surge, so for starting load: no data. Retrieved 2026-10-02. CSV, 5 rows.
Assumptions (our scenario): one refrigerator, one television, two ceiling fans and one window air conditioner, all at their median running watts, add up to about 917 W. Swap the window unit for a central 3-ton system and the total is about 2,376 W. These are the medians in the lists, not your appliances; start from your own nameplates. For food and fridge rules see what to do in a power outage, and for hot weather heat waves and air conditioning costs.
What this page cannot tell you
The CPSC counts come from reports to CPSC staff and are a minimum. We have no data on how many generators are in use, on fuel use or run times, or on any single model. The staff report is a staff document that CPSC marks as not reviewed or accepted by the Commission. For current guidance, use the CPSC pages linked in the table.
Key facts and where they come from
| Fact | Value | Source | Date |
|---|---|---|---|
| CO deaths a year, consumer products, non-fire | More than 200 | CPSC, Carbon Monoxide Information Center, cpsc.gov | retrieved 2026-10-02 |
| Of those, linked to portable generators | More than 100 | CPSC, Carbon Monoxide Information Center, cpsc.gov | retrieved 2026-10-02 |
| Minimum distance from home for a generator | At least 20 feet, exhaust facing away | CPSC, Carbon Monoxide Information Center, cpsc.gov | retrieved 2026-10-02 |
| Same distance, FEMA wording | At least 20 feet from windows, doors and attached garages | FEMA Ready.gov, Power Outages, ready.gov/power-outages | retrieved 2026-10-02 |
| Generator CO deaths in report, 2012 to 2022 | 789 | CPSC staff report, Fatal Incidents Associated with Non-Fire CO Poisoning from Engine-Driven Generators and Other Engine-Driven Tools, 2012-2022 (Apr. 2023 data) | April 2023 data |
| Generator-only deaths, 2012 to 2022 | 749 (86% of all engine-driven tool deaths, 872) | CPSC staff report, Fatal Incidents Associated with Non-Fire CO Poisoning from Engine-Driven Generators and Other Engine-Driven Tools, 2012-2022 (Apr. 2023 data) | April 2023 data |
| Deaths in fixed-structure homes, generators | 553 deaths in 414 incidents | CPSC staff report, Fatal Incidents Associated with Non-Fire CO Poisoning from Engine-Driven Generators and Other Engine-Driven Tools, 2012-2022 (Apr. 2023 data) | April 2023 data |
| No apparent ventilation attempted, home deaths with data | 66% | CPSC staff report, Fatal Incidents Associated with Non-Fire CO Poisoning from Engine-Driven Generators and Other Engine-Driven Tools, 2012-2022 (Apr. 2023 data) | April 2023 data |
| Deaths where an alarm was known to be present | 33 (4%) | CPSC staff report, Fatal Incidents Associated with Non-Fire CO Poisoning from Engine-Driven Generators and Other Engine-Driven Tools, 2012-2022 (Apr. 2023 data) | April 2023 data |
| Deaths in the four colder months | 45% | CPSC staff report, Fatal Incidents Associated with Non-Fire CO Poisoning from Engine-Driven Generators and Other Engine-Driven Tools, 2012-2022 (Apr. 2023 data) | April 2023 data |
| Standards CPSC names for CO safety technology | PGMA G300-2023 and UL 2201-2023 | CPSC news release, May 27, 2026, cpsc.gov | retrieved 2026-10-02 |
| Window air conditioner, median running power | 709 W | ENERGY STAR product list, via data/appliances_es.json | 2 Oct 2026 |
| Central 3-ton air conditioner, median running power | 2,169 W | ENERGY STAR heat pump list, via data/appliances_es.json | 2 Oct 2026 |
Related guides
Questions
How far from the house must a generator be?
CPSC says at least 20 feet from homes and buildings, outdoors only, with the exhaust directed away from windows, doors and vents. Ready.gov gives the same 20 feet.
Is it safe to run a generator in the garage with the door open?
No. CPSC says never use a portable generator inside homes, garages, basements, crawlspaces or sheds, even with doors or windows open.
How many people die from generator CO?
CPSC says more than 100 deaths a year are linked to portable generators. Its staff report counts 789 reported generator-related deaths from 2012 to 2022, a minimum.
What are the symptoms of CO poisoning?
Headache, dizziness, weakness, nausea, vomiting, sleepiness and confusion, per CPSC. Get outside to fresh air and call 911.
Do CO alarms help?
CPSC says to install one on every level and outside sleeping areas. In its report only 33 deaths, 4%, were in incidents with a known alarm, and in 17 of those the alarm was not working.
What is a CO shut-off generator?
A model that shuts off when dangerous CO builds nearby. CPSC says to look for it and for PGMA G300-2023 and UL 2201-2023 certification, but still run it 20 feet away.
Can I use a gas stove or oven to heat my home in an outage?
No. Ready.gov says it increases the risk of carbon monoxide poisoning and can cause fires and burns.
What can a generator safely run?
We cannot say; check your generator's manual. For scale, the median window air conditioner runs at about 709 W and a central 3-ton system at about 2,169 W, from ENERGY STAR lists.